zur Suche springenzur Navigation springenzum Inhalt springen

Publikationen - Molekulare Signalverarbeitung

Sortieren nach: Erscheinungsjahr Typ der Publikation

Zeige Ergebnisse 1 bis 3 von 3.

Publikation

Ziegler, J.; Abel, S.; Analysis of amino acids by HPLC/electrospray negative ion tandem mass spectrometry using 9-fluorenylmethoxycarbonyl chloride (Fmoc-Cl) derivatization Amino Acids 46, 2799-2808, (2014) DOI: 10.1007/s00726-014-1837-5

A new method for the determination of amino acids is presented. It combines established methods for the derivatization of primary and secondary amino groups with 9-fluorenylmethoxycarbonyl chloride (Fmoc-Cl) with the subsequent amino acid specific detection of the derivatives by LC–ESI–MS/MS using multiple reaction monitoring (MRM). The derivatization proceeds within 5 min, and the resulting amino acid derivatives can be rapidly purified from matrix by solid-phase extraction (SPE) on HR-X resin and separated by reversed-phase HPLC. The Fmoc derivatives yield several amino acid specific fragment ions which opened the possibility to select amino acid specific MRM transitions. The method was applied to all 20 proteinogenic amino acids, and the quantification was performed using l-norvaline as standard. A limit of detection as low as 1 fmol/µl with a linear range of up to 125 pmol/µl could be obtained. Intraday and interday precisions were lower than 10 % relative standard deviations for most of the amino acids. Quantification using l-norvaline as internal standard gave very similar results compared to the quantification using deuterated amino acid as internal standards. Using this protocol, it was possible to record the amino acid profiles of only a single root from Arabidopsis thaliana seedlings and to compare it with the amino acid profiles of 20 dissected root meristems (200 μm).
Publikation

Kramell, R.; Miersch, O.; Schneider, G.; Wasternack, C.; Liquid chromatography of jasmonic acid amine conjugates Chromatographia 49, 42-46, (1999) DOI: 10.1007/BF02467185

Racemic jasmonic acid (3R,7R/3S,7S)-(±)-JA) was chemically conjugated with different biogenic amines originating from aliphatic and aromatic α-amino acids by decarboxylation. The resulting isomeric compounds were subjected to reversed-phase high-performance liquid chromatography (HPLC) and to HPLC on the chiral stationary phases Chiralpak AS and Nucleodex β-PM. Under reversed-phase conditions, all the homologous amine derivatives tested could be separated from each other except the JA-conjugates containing 2-phenyl-ethylamine and 3-methylbutylamine. On both chiral supports the (3R,7R)-(−)-JA conjugates eluted earlier than those of the enantiomeric counterpart (3S,7S)-(+)-JA. On Chiralpak AS all the isomers studied could be separated to baseline with a mobile phase containingn-hexane and 2-propanol. The calculated resolution factors were between 1.80 and 4.17. The pairs of isomers were also chromatographed on the cyclodextrin stationary phase Nucleodex β-PM with methanol-triethylammonium acetate buffer as mobile phase. Under these conditions resolution factors were between 0.74 and 1.29. The individual isomers were chiroptically characterized by measurement of their circular dichroism.
Publikation

Kramell, R.; Schneider, G.; Miersch, O.; Chiral separation of amide conjugates of jasmonic acid by liquid chromatography Chromatographia 45, 104-108, (1997) DOI: 10.1007/BF02505545

Synthetic amide conjugates of (−)-jasmonic acid and its (+)-enantiomer were resolved by means of chiral liquid chromatography. The diastereomeric pairs prepared by chemical reaction of (±)-jasmonic acid with a series of (S)- or (R)-amino acids and with some (S)-amino acid alcohols were completely separated on Chiralpak AS using a mixture of n-hexane/2-propanal as mobile phase. The retention data indicate that the (−)-jasmonic acid conjugates eluted faster than those of the (+)-enantiomer, independent on the configuration of the bound amino acid. Likewise, enantiomeric derivatives of (±)-jasmonic acid and non-chiral amino acids were completely separated on the chiral stationary phase and showed the same elution sequence. The resolution factors,Rs, were found to range between 1.13 and 6.64. The separated compounds were chiropatically analyzed by measurement of the circular dichroism.
IPB Mainnav Search